Super Industrial Lining Pvt Ltd - | E-Showroom
Super Industrial Lining Pvt Ltd - | E-Showroom
Size (NB) | L ± 5 | OD ± 1 | T ± 1 | R/F ± 1 | PCD ± 1 | Hole Dia. | No. of Hole | L1 ± 4 | L2 ± 4 |
mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
50 | 228 | 152.4 | 19 | 92.1 | 120.6 | 19 | 4 | 114 | 75 |
80 | 280 | 190.5 | 23.8 | 127 | 152.4 | 19 | 4 | 140 | 75 |
100 | 330 | 228.6 | 23.8 | 157.2 | 190.5 | 19 | 4 | 165 | 75 |
150 | 406 | 279.4 | 25.4 | 215.9 | 241.3 | 22 | 4 | 203 | 75 |
200 | 558 | 342.9 | 28.6 | 269.9 | 298.4 | 22 | 4 | 558 | 75 |
Sr. No. | Description | Qty. | Material |
1 | Body Shell | - | 2" x Sch. 40, ASTM A. 106 Gr. B + PFA, FEP, PVDF, PP, HDPE Lined |
2 | Cover | - | 2" Flange, ASTM A. 105 N + PFA, FEP, PVDF, PP, HDPE Lined CL 150# |
3 | Nozzle Flange | - | 2" Flange CL150#, ASTM A. 105N+PFA, FEP, PVDF, PP, HDPE Lined |
4 | Drain Pipe | - | 3/4" x Sch. 80, ASTM A. 106 Gr. B + PFA, FEP, PVDF, PP, HDPE Lined |
5 | Drain Flange | - | 3/4" CL 150#, ASTM A. 105 N + PFA, FEP, PVDF, PP, HDPE Lined |
6 | Fasteners | - | ASTM A. 193 Gr. B 7/A. 194 Gr.2 H + PTFE Top Coated |
General Notes | Casting Material | |||
Design Standard | Manufacturing Standard | Ductile Iron | ASTM A 395 | |
Test Standard | API 598 / ISO 9393 - 2 / BS EN 12266 - 1:2003 | Cast Iron | ASTM A 216 Gr. WCB | |
Dimension Standard | ANSI B 16.10 | Stainless Steel | ASTM A 351 CF 8 / ASTM A 351 CF 8M | |
Face to Face Dimension | ANSI B 16.5 | |||
Flange Connection | ANSI B 16.5; 150#; RF |
Hydro - Test Pressure | Spark Test | ||
Size : 50 to 100 NB | Body : 10 kg/cm² | 15 kv dc | |
Size : 150 to 200 NB | Body : 05 kg/cm² |